Type III Break-Away Barricade
PLA-304-EGL-DRILL-KITThe All-Plastic Break-Away is a Type III Barricade Composed of two Plastic Power Post, two feet assembly, and three Power Boards available in various sizes, sheeting grades and designs. The Posts and feet are made of impact resistant polymer plastic.
Features and Benefits:
- Collapsible for efficient transportation and storage
- Universal mounting holes make assembling this barricade quick and easy
- Accepts two barricade lights for night visibility
- Durable plastic 1" x 8" board won’t rot or rust like metal and wood
- Order 3M retroreflective sheeting in various direction configurations and grades for one or both board sides
- Ensures high visibility
- Helps guide traffic
- Kit includes everything you need to set up the barricade
- Component parts also available individually
- MASH Accepted, WZ- 299 - Meets MUTCD Standards
- Proudly made in the USA
Made in the USA
If you would like to request a quotation for large quantities of this or any other products, please email us at sales@linedividers.com or call us at 1-800-288-2832
Technical Specifications:
- Dimensions: 60"H x 60"L
- Built Barricade Weight: 29 lbs.
- Collapsible
- Universal mounting holes, accepts two barricade lights.
- Plastic 1" x 8" board available in 4', 6', 8', 10', and 12'
- None, one or both sides with 3M retroreflective striped sheeting in EG, HIP & DG
- Kits with assembly hardware included
- Added component parts also available individually
- MASH Accepted, WZ- 299 - Meets MUTCD Standards
Technical Documents and Certifications:
State Reference Guide
Learn more about traffic product certifications and specifications for your state.
Alaska
No QPL
AK Standard Specifications
AK Standard Drawings
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Arizona
No QPL
AZ State Supplement
AZ Traffic Control Guidelines
AZ Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Arkansas
No QPL
AR Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956 Type VII, Type VIII, or Type IX
Plasticade meets the specification by supplying 3M™ Diamond Grade™
California
CA QPL
CA State Manual
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type I/II
Plasticade meets the specification by supplying 3M™ Engineer Grade
Colorado
CO QPL
CO DOT
CO Work Zone Devices
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Connecticut
CT QPL
CT Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Delaware
No QPL
DE DOT
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Georgia
GA QPL
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
No QPL
HI Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Illinois
No QPL
IL State Supplement
IL Standard Specifications
IL Design Standards
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III/IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Indiana
No QPL
IN State Manual 2011
IN Work Zone Devices
IN Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Iowa
IA QPL
IA Traffic Safety Manual
Certified for use:
DOT Sheeting Requirement – ASTM D4956 Type VII non-fluorescent
Plasticade meets the specification by supplying 3M™ Diamond Grade™
Only use 6' boards
Kansas
KS QPL
KS Standard Specifications
KS Special Provisions
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Kentucky
No QPL
KY Standard Specifications
KY Standard Drawings
Approved Materials
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Maine
Maine QPL
ME Temporary Traffic Control
ME Standard Specifications
Under evaluation
Maryland
MD QPL
MD State Manual
Certified for use
Massachusetts
MA QPL
MA MUTCD
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Michigan
No QPL
MI State Manual
MI Work Zone Device Drawings
MI Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Minnesota
Minnesota QPL
MN State Manual
MN Work Zone Devices
MN Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956 Type XI
Plasticade meets the specification by supplying 3M™ Diamond Grade™
Mississippi
MS QPL
MS Standard Drawings
MS Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Missouri
No QPL
MO State Manual
Standards and Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Montana
MT QPL
MT Standard Drawings
MT Manuals and Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Nebraska
NE QPL
NE Standard and Special Plans Manual
Certified for use:
DOT Sheeting Requirement – ASTM D4956 Type XI
Plasticade meets the specification by supplying 3M™ Diamond Grade™
New Hampshire
No QPL
NH DOT
NH Notes to MUTCD
NH Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
New Mexico
No QPL
NM Standard Specifications
Certified for use
New York
No QPL
NY State Supplement
NYSDOT Standard Drawings
NY Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type I or Type III
Plasticade meets the specification by supplying 3M™ Engineer Grade or 3M™ High Intensity Prismatic Grade
North Dakota
No QPL
ND Work Zone Devices
ND Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Ohio
OH APL
OH State Manual
Temporary Traffic Control Manual
Traffic Control for Work Zones Guidelines
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
OK QPL
OK Work Zone Devices
OK Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade Use with 4', 6', 8', 10', or 12' lengths
Pennsylvania
PA QPL
Approved Products for Lower Volume Roads
PA State Supplement
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Rhode Island
No QPL
Approved Materials List
RI Standard Details
RI Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
South Carolina
SC QPL and MUTCD Supplement
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
South Dakota
No QPL
SD Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Tennessee
TN QPL
Certified for use
Utah
UT APL
UT State Manual
UT Work Zone Devices
UT Standard Specifications
Certified for use:
Use only 4' rails. DOT Sheeting Requirement – ASTM D4956 Type XI
Plasticade meets the specification by supplying 3M™ Diamond Grade™ Certified for use. 8""-12"" rails; 4' minimum length.
Vermont
No QPL
VT DOT
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Virginia
No QPL
VA Roadside and Safety Devices
VA State Supplement
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Washington
WA QPL
WA State MUTCD
WA Design Standards
WA Traffic Manual
WA Standard Plans
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Washington DC
No QPL
DC Standard Specifications
DC Temporary Traffic Control Manual
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
West Virginia
No QPL
WV State Supplement
WV Special Provisions
WV Standard Specifications
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Wisconsin
No QPL
WI State Supplement
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Wyoming
No QPL
WY Standard Work Zone Devices
WY MUTCD
Certified for use:
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade