Type II Combocade Construction Barricades
PLA-105G-T8B6The Combocade Construction Barricade is a traffic safety device composed of galvanized steel legs and 2 plastic power boards available in various sizes and styles. They meet MUTCD Standards and are MASH accepted.
Features and Benefits:
- Type II Barricade with none or both boards sheeting for personalization and visibility
- Double-walled for extra durable barricades
- High quality 14 gauge thickness galvanized steel for an elegant and resistant appearance
- Stenciling available for easy recognition
- Various sheeting grades and styles to adapt to any need
- Component Parts and Power Boards available separately
- Available as Type I Combocade Construction Barricades
- Simple design that is durable and economical
The Combocade construction barricade is a simple device designed to be economical and long-lasting, made of 14 gauge thickness Galvanized steel legs and double-walled strong boards. The boards won't crack under sandbags and come with reinforced bolt/rivet holes for easy and quick one-person application.
Available in 8" x 24" or 12" x 24" for the top board and 8" x 24" or 6" x 24" for the bottom board, these power boards can be personalized with stripped sheeting or any custom design in 3M - Engineer, High Intensity Prismatic or Diamond Grade sheeting. The steel legs can be used with sandbags for additional ballast. They are MASH Accepted (WZ-406), tested with a lightweight warning light and meet MUTCD Standards.
Made in the USA
If you would like to request a quotation for large quantities of this or any other products, please email us at sales@linedividers.com or call us at 1-800-288-2832
Technical Specifications:
- Legs: 14 gauge thickness Galvanized steel
- Boards: Double-walled plastic
- Boards also available separately
- Stenciling available
- Legends applied professionally
Call to choose your legend option
State Reference Guide
Learn more about traffic product certifications and specifications for your state.
Alabama
AL QPL
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Alaska
No QPL
AK Standard Specifications
AK Standard Drawings
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Arizona
No QPL
AZ State Supplement
AZ Traffic Control Guidelines
AZ Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
8" x 24" sheeting panels
Arkansas
No QPL
AR Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type II/III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
California
CA QPL
CA State Manual
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type I
Plasticade meets the specification by supplying 3M™ Engineer Grade
Colorado
CO QPL
CO DOT
CO Work Zone Devices
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type II, Type III, or Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Connecticut
CT QPL
CT Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Florida
Florida QPL
Florida Standard Specifications
Certified for use:
Type I - cannot use, requires 12" x 36" panel
Type II - certified for use - 102-001-036
Products must have the approval number stenciled or stamped on unit
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Hawaii
No QPL
HI Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III/IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Idaho
Idaho QPL
ID State Supplement
ID Traffic Manual
Certified for use:
Certified for use.
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Illinois
No QPL
IL State Supplement
IL Standard Specifications
IL Design Standards
Certified for use:
Certified for use.
DOT Sheeting Requirement – ASTM D4956, Type III/IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Indiana
No QPL
IN State Manual 2011
IN Work Zone Devices
IN Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Iowa
IA QPL
IA Traffic Safety Manual
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956 Type VII non-fluorescent
Plasticade meets the specification by supplying 3M™ Diamond Grade™
Kentucky
No QPL
KY Standard Specifications
KY Standard Drawings
Approved Materials
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Massachusetts
MA QPL
MA MUTCD
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Minnesota
Minnesota QPL
MN State Manual
MN Work Zone Devices
MN Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956 Type XI
Plasticade meets the specification by supplying 3M™ Diamond Grade™
Missouri
No QPL
MO State Manual
Standards and Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Montana
MT QPL
MT Standard Drawings
MT Manuals and Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Nebraska
NE QPL
NE Standard and Special Plans Manual
Certified for use:
Certified for use, Type II only, Type I barricades are not allowed
DOT Sheeting Requirement – ASTM D4956, diamond grade
Plasticade meets the specification by supplying 3M™ Diamond Grade™
New Hampshire
No QPL
NH DOT
NH Notes to MUTCD
NH Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
New York
No QPL
NY State Supplement
NYSDOT Standard Drawings
NY Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type I to Type III
Plasticade meets the specification by supplying 3M™ Engineer Grade or 3M™ High Intensity Grade
North Dakota
No QPL
ND Work Zone Devices
ND Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Rhode Island
No QPL
Approved Materials List
RI Standard Details
RI Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
South Carolina
SC QPL and MUTCD Supplement
Certified for use:
Under evaluation for Type II barricade, no Type I barricades allowed
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
South Dakota
No QPL
SD Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Utah
UT APL
UT State Manual
UT Work Zone Devices
UT Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, diamond grade
Plasticade meets the specification by supplying 3M™ Diamond Grade™
Vermont
No QPL
VT DOT
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Virginia
No QPL
VA Roadside and Safety Devices
VA State Supplement
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Washington
WA QPL
WA State MUTCD
WA Design Standards
WA Traffic Manual
WA Standard Plans
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
No QPL
DC Standard Specifications
DC Temporary Traffic Control Manual
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
West Virginia
No QPL
WV State Supplement
WV Special Provisions
WV Standard Specifications
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type III
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Wisconsin
No QPL
WI State Supplement
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade
Wyoming
No QPL
WY Standard Work Zone Devices
WY MUTCD
Certified for use:
Certified for use
DOT Sheeting Requirement – ASTM D4956, Type IV
Plasticade meets the specification by supplying 3M™ High Intensity Prismatic Grade